Region

Wallonia

How to manage the safety data sheets you receive in Wallonia: French SDS, and the SDS data that decides your storage class and environmental permit.

Reviewed 17 November 2026 ENFRDE

Quick answer

In Wallonia, get a current SDS in French (German in the German speaking area) for every hazardous product you store and use it to manage your store: the CLP hazard class and category in section 2 and the flash point in section 9 decide where you fall under heading (rubrique) 63.12 of the list of classified installations. Add up your stored quantities per hazard class: class 3 needs a declaration, class 2 a permit and class 1 a permit with an impact study.

What it is

Wallonia adds its own environmental rules on top of the federal Belgian rules. Workplace safety, the exposure limits, product rules and the SDS language rule stay federal: see Belgium. The environmental permit decree sorts installations into three classes: class 3 needs a declaration, class 2 a permit and class 1 a permit with an impact study. Storage of hazardous substances falls mainly under heading 63.12 (AGW of 4 July 2002), which uses CLP hazard classes and categories from section 2 of the SDS. Wallonia has no workplace exposure limits of its own.

Does it apply to you?

  • You store hazardous substances or mixtures in Wallonia above the heading 63.12 thresholds, for example 50 l of category 1 flammable liquids or 10 kg of acute toxicity category 1.
  • You store diesel or heating oil in fixed tanks from 3000 l.
  • You hold substances named in the Seveso annex, or enough hazardous substances to be a Seveso site: every Seveso site is class 1.
  • You use organic solvents (VOC headings), discharge industrial wastewater or produce hazardous waste.

Managing your safety data sheets

Task What applies in Wallonia
Get an SDS for every hazardous product Ask your supplier for the SDS of every product you store; the storage headings are built on the CLP classification in section 2.
Check the language and version The SDS must be in French, or German in the German speaking area (federal royal decree of 7 September 2012). Check that you hold the latest version.
Keep SDS current Suppliers update the SDS when new information on hazards or risk management becomes available (REACH article 31). Replace old versions: a new classification can change your class under heading 63.12.
Give workers access Federal rule: workers must have access to the SDS of the hazardous products they handle (Codex art. VI.1-27).
Use them in the risk assessment Federal rule (Codex art. VI.1-6). For storage, read section 2 (CLP class and category), section 3 (named substances), section 9 (flash point) and sections 7 and 10 (storage and incompatibilities).
Keep a chemical inventory The permit application forms ask for information on the products you store, which in practice comes from your SDS. Keep your stored quantities per hazard class up to date.
What an inspector asks Your declaration or permit, quantities per hazard class within what it allows, tank overfill devices and tightness tests, and the prevention of explosive atmospheres and emissions.

What you need to do

  1. Collect a current SDS in French (or German) for every stored hazardous product.
  2. Sum your stored products per CLP hazard class and category and compare them with heading 63.12.
  3. File a declaration (class 3) or apply for a permit (class 2 or class 1) when you reach a threshold.
  4. Use the flash point to place flammable and combustible liquids in the right subheading.
  5. Check whether you store any substance named in heading 63.12.23, such as phosgene, arsine or methyl isocyanate.
  6. Fit fixed tanks for combustible liquids with an overfill device and, for single wall tanks, a tight bund at least as large as the largest tank.
  7. Have tanks tested for tightness by an approved technician or competent expert.
  8. Prevent explosive atmospheres and emissions of dangerous products, as the general operating conditions require.
  9. Check solvent consumption against the VOC headings, with lower thresholds for H340, H350, H350i, H360D or H360F.
  10. Classify waste from your products using the hazardous properties HP 1 to HP 15.
  11. Check the federal exposure limits and carcinogen lists on the Belgium page; they also apply in Wallonia.

What NextSDS checks for you

Check SDS data used What it tells you
Storage thresholds (heading 63.12) Section 2 (CLP class and category), section 9 (flash point) Which class your stored quantities reach per hazard
Named Seveso substances (heading 63.12.23) Section 3 (composition) Whether you store a named substance that needs a permit
Combustible liquid tanks Section 9 (flash point) Whether the tank conditions for combustible liquids apply
Seveso thresholds Section 2 (classification), section 3 (named substances) Which products count towards the lower and upper tier
CMR solvents (VOC headings) Section 2 (H statements), sections 3 and 9 (VOC content) Whether lower solvent thresholds apply
Hazardous waste Sections 2, 3 and 13 Whether waste from a product is likely hazardous

Key lists and limits

  • Storage headings 63.12 (AGW of 4 July 2002, annex I): thresholds per CLP hazard class and category for class 3, 2 and 1. Official text
  • Named Seveso substances (heading 63.12.23): substances from Seveso annex I part 2 that need a permit.
  • Seveso thresholds (cooperation agreement of 16 February 2016): lower and upper tier quantities per hazard category and named substance. Official text
  • Priority substances and water quality standards (Code de l’Eau, annexes I, Xbis and XIV): substances with CAS numbers that matter for discharges. Official annexes
  • Soil threshold values (soil decree, annex 1): values per land use type for metals, BTEX, phenol and PAH. Official annex
  • Indoor air guide values (AGW of 30 May 2024): values for the general population, not for workplaces; never use them as exposure limits.
  • Federal lists: exposure limits and carcinogen lists apply in Wallonia, see Belgium.

Key dates

  • 29 November 2024: current version of the list of classified installations.
  • 10 August 2023: the 1996 waste decree ended; the decree of 9 March 2023 now applies.
  • 1 September 2019: CLP based storage headings in force (AGW of 16 May 2019).

Frequently asked questions

Which SDS data decides the Walloon storage class?

The CLP hazard class and category in section 2 decide the subheading, and the flash point in section 9 places flammable and combustible liquids. Section 3 shows whether you store a named substance from heading 63.12.23.

In which language must the SDS I receive be in Wallonia?

In French, or in German in the German speaking area. The language rule is federal (royal decree of 7 September 2012).

Do I need SDS data for a permit application in Wallonia?

Yes, in practice. The permit application forms ask for information on the products you store, such as their hazard class and quantities, which comes from your SDS.

Which exposure limits should I compare with section 8 of the SDS in Wallonia?

The federal limits of Codex annex VI.1-1. Wallonia has no workplace limits of its own, and its indoor air guide values are for the general population, not workplaces.

What is rubrique 63.12 in Wallonia?

It is the group of headings in the Walloon list of classified installations that covers storage of hazardous substances and mixtures. Its thresholds are set per CLP hazard class and category and decide whether you need a declaration or a permit.

What are the permit classes in Wallonia?

Class 3 installations need a declaration, class 2 installations need an environmental permit and class 1 installations need a permit with an environmental impact study. Every Seveso site is class 1.

Since when does Wallonia use CLP categories for storage?

Since 1 September 2019, when the AGW of 16 May 2019 brought in the CLP based storage headings.

Does a diesel or heating oil tank need a permit in Wallonia?

Fixed tanks of diesel or heating oil fall under the classified installations from 3000 l. Fixed tanks for combustible liquids also need an overfill device, a tightness test and, for single wall tanks, a tight bund.

  • Belgium: federal workplace rules, exposure limits and SDS language rule that also apply in Wallonia.
  • Flanders: the Flemish equivalent, with storage under VLAREM heading 17.
  • Brussels: the Brussels equivalent, with storage under headings 88 and 121.
  • ISO 14001: its compliance obligations include your Walloon permit conditions.

Official sources

Based on research of 17 November 2026. This page is not legal advice; always check the official text.

2,437 SDSs. None left to chase.

Managing safety data sheets under Wallonia rules? NextSDS tracks down every SDS from your suppliers, processes all 16 sections and checks each one against current regulations.